Storage, making and breaking by motor, It can operating by handle.<br>Breaking short-circuit current up to 25kA.<br>Mini motor spring mechanism (about 30W).<br>Installation method: adopt two type installation method.<br>Sealing performance: adopt reliable sealing technical.<br>Incoming & Outgoing method:adopt silicon bushing to make enough insulate distance<br>Safe operating: there is an equipment to protect explosion.

Specifications

VS1(ZN63 ) series vacuum circuit breaker is an indoor three-phase AC high-voltage switchgear of 50 Hz and rated voltage 12KV, made by introducing the technology of Swiss ABB Company and according to domestic industrial development and production capacity. The entire structure of this product presents the integrated installation of switch body and operating mechanism. It adopts the composite insulation structure, with high insulation level, no pollution or explosion danger. Its operating mechanism is of spring energy-storage type, which be operated with alternating current or by manual.

Technical Data

Item unit parameter
Rated voltage kV 12
Rated insulation level 1 min line frequency withstand voltage kV 42
rated thunder impulse withstand voltage kV 75
Rated current A 630,1250,1600,2000
Rated short circuit breaking current kA 20,25,31.5,40
Rated short circuit closing current kA 50,63,80,100
Rated peak withstand current kA 50,63,80,100
Rated short circuit withstand current(effective value) kA 20,25,31.5,40
Rated current breaking times times 50
Rated short-circuit duration S 4
Rated operating sequence times O-0.3s-CO-180s-CO
Mechanical life times 20000
Rated single capacitor bank breaking current A 630
Rated back-to-back capacitor bank breaking current A 400
Contactor torque mm 11 1
Contact stroke mm 3 0.5
Three-phase opening synchronization ms ≤2
Closing bounce time ms ≤2
Phase-to-phase distance mm 210 1.5(275 1.5)
Contact pressure of closing contact N 3200 100
Average break brake speed m/s 0.9~1.2
Average close brake speed m/s 0.55~0.8
Breaking time ms 20~50
Closing time ms 35~70
Accumulative Allowable Wear Thickness of Dynamic and Static Contacts mm 3

See how orders move from review to dispatch.

Reception, production, testing and shipment areas are organized to keep technical requirements, work progress and delivery records aligned.
Workplace & Customer Reception

Workplace & Customer Reception

Visitors and project teams have a clear place to review requirements, drawings and delivery details before work moves forward.
Organized Production Lines

Organized Production Lines

Defined work areas and orderly material flow help teams keep assemblies, components and order information aligned.
Testing & Verification

Testing & Verification

Routine checks and functional verification are completed against approved requirements before release.
Shipment & Delivery

Shipment & Delivery

Finished orders are checked, protected and organized for traceable handover and coordinated dispatch.

Built for recognised standards

Our documentation package supports project review with internationally recognised safety, quality and environmental marks.

Technical files for your review

Access the latest catalogue, technical parameters and certification files before you finalise your specification.
Go to Download Center

Product questions, answered

Clear guidance on selection, documentation, customization and project delivery.
Please provide the application, system rated voltage and frequency, continuous load current, short-circuit level, insulation level or BIL, and the required operating duty. Also include indoor or outdoor installation, altitude, ambient temperature, pollution level, control voltage, communication requirements, quantity, destination market and applicable standard. A single-line diagram, existing nameplate or project specification will make the review more accurate.
Product Enquiry

Define the right product configuration

Share the application and commercial information available at this stage. Our team will review the request against the product range and identify any details still required for quotation.

Application data

Rated voltage, installation environment and operating duty.

Technical scope

Applicable standard, configuration and required documents.

Delivery planning

Estimated quantity, destination and requested schedule.

Project details

Complete the fields below and include any specification points already confirmed.
询盘表单