Current Transformers

Current Transformers

Current Transformer LZZBW-35W3

Application: 40.5kV outdoor overhead power line<br>Structure: Outdoor, single phase, resin casting, and support type<br>Rated frequency: 50Hz, 60Hz<br>Rated insulation level: 40.5/95/185kV (IEC 36/70/170kV)<br>Rated secondary current: 5A, 1A<br>Standard: GB/T 20840.1 & 2 (IEC 61869-1 & 2)

Technical Data

Rated primary current(A)

Accuracy combination

Rated output (VA)

Protective accuracy limit factor (ALF)

Rated short-time thermal current Ith(kA/s)

Dynamic current Idyn(kA)

0.2 (0.2S)

0.5 (0.5S)

5P (10P)

5, 10, 15, 20, 25, 30, 40, 50, 75,100, 150, 200

0.2 (S)/0.2 (S)
0.2 (S)/0.5 (S)
0.2 (S)/10P
0.5 (S)/10P
0.2 (S)/0.5 (S)/10P
0.2 (S)/10P/10P
0.2 (S)/0.5 (S)/10P/10P

15
20
30

15
20
30

15
20
30

10
15
20
30

150I1n

375I1n

250, 300

31.5/2

80

400, 500

31.5/3

80

600, 750

45/2

100

800, 1000

45/3

100

1200, 1500

63

130

2000, 2500

80

160

Remarks: Customizable secondary winding tapping and multi-ratio design.

★ Warning: Prohibit secondary open circuit.

Outline Drawing

CURRENT TRANSFORMER LZZBW-35W3 (PO-401)-1.jpg

See how orders move from review to dispatch.

Reception, production, testing and shipment areas are organized to keep technical requirements, work progress and delivery records aligned.
Workplace & Customer Reception

Workplace & Customer Reception

Visitors and project teams have a clear place to review requirements, drawings and delivery details before work moves forward.
Organized Production Lines

Organized Production Lines

Defined work areas and orderly material flow help teams keep assemblies, components and order information aligned.
Testing & Verification

Testing & Verification

Routine checks and functional verification are completed against approved requirements before release.
Shipment & Delivery

Shipment & Delivery

Finished orders are checked, protected and organized for traceable handover and coordinated dispatch.

Built for recognised standards

Our documentation package supports project review with internationally recognised safety, quality and environmental marks.

Technical files for your review

Access the latest catalogue, technical parameters and certification files before you finalise your specification.
Go to Download Center

Product questions, answered

Clear guidance on selection, documentation, customization and project delivery.
Please provide the application, system rated voltage and frequency, continuous load current, short-circuit level, insulation level or BIL, and the required operating duty. Also include indoor or outdoor installation, altitude, ambient temperature, pollution level, control voltage, communication requirements, quantity, destination market and applicable standard. A single-line diagram, existing nameplate or project specification will make the review more accurate.
Product Enquiry

Define the right product configuration

Share the application and commercial information available at this stage. Our team will review the request against the product range and identify any details still required for quotation.

Application data

Rated voltage, installation environment and operating duty.

Technical scope

Applicable standard, configuration and required documents.

Delivery planning

Estimated quantity, destination and requested schedule.

Project details

Complete the fields below and include any specification points already confirmed.
询盘表单